Title: Elimination of dual slope from the Coffin-Manson relationship of low-cycle fatigue in the titanium alloy timetal 834, by cold rolling
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
Cold rolling of the titanium alloy Timetal 834 was found to cause marked enhancement in low-cycle fatigue (LCF) life at low strain amplitude and to eliminate bilinear behavior from the Coffin-Manson (C-M) relationship. It was due to work hardening of surface grains of soft orientation and consequent increase in resistance of the material against crack initiation. The observed effect was not associated with texture. © The Minerals, Metal & Materials Society and ASM International 2007.