A self assembled monolayer based microfluidic sensor for urea detection

dc.contributor.authorSaurabh Srivastava
dc.contributor.authorPratima R. Solanki
dc.contributor.authorAjeet Kaushik
dc.contributor.authorMd. Azahar Ali
dc.contributor.authorAnchal Srivastava
dc.contributor.authorB.D. Malhotra
dc.date.accessioned2026-02-07T05:26:42Z
dc.date.issued2011
dc.description.abstractUrease (Urs) and glutamate dehydrogenase (GLDH) have been covalently co-immobilized onto a self-assembled monolayer (SAM) comprising of 10-carboxy-1-decanthiol (CDT) via EDC-NHS chemistry deposited onto one of the two patterned gold (Au) electrodes for estimation of urea using poly(dimethylsiloxane) based microfluidic channels (2 cm × 200 μm × 200 μm). The CDT/Au and Urs-GLDH/CDT/Au electrodes have been characterized using Fourier transform infrared (FTIR) spectroscopy, contact angle (CA), atomic force microscopy (AFM) and electrochemical cyclic voltammetry (CV) techniques. The electrochemical response measurement of a Urs-GLDH/CDT/Au bioelectrode obtained as a function of urea concentration using CV yield linearity as 10 to 100 mg dl-1, detection limit as 9 mg dl -1 and high sensitivity as 7.5 μA mM-1 cm-2. © 2011 The Royal Society of Chemistry.