Title:
CORROSION RESISTANCE OF TWO MAGNETIC METALLIC GLASSES IN ACIDIC AND NEUTRAL AQUEOUS SOLUTIONS.

dc.contributor.authorI.B. Singh
dc.contributor.authorR.S. Chaudhary
dc.contributor.authorT.K.G. Namboodhiri
dc.date.accessioned2026-02-09T09:47:53Z
dc.date.issued1986
dc.description.abstractThe corrosion resistance of two magnetic metallic glasses, viz. Fe//4//0Ni//4//0B//2//0 and Fe//3//9Ni//3//9Mo//2 (SiB)//2//0 was evaluated in H//2SO//4 and NaCl solutions by weight loss measurement and electrochemical techniques. In exposures up to six days the corrosion rate of Fe//4//0Ni//4//0B//2//0 was about 5 mpy while Fe//3//0Ni//3//9Mo//2 (SiB)//2//0 corroded about two times faster in 0. 1 M H//2SO//4 solution. In 3. 5% NaCl both alloys corroded at about the same rate, nearly 2 mpy. In potentiostatic polarization measurements the Mo bearing alloy passivated in the potential range plus 0. 45 V to plus 1. 45 V with respect to saturated calomel electrode in H//2SO//4 solutions of concentration 0. 001 M to 0. 1 M, but both alloys failed to passivate in NaCl solutions.
dc.identifier.issn0013466X
dc.identifier.urihttps://dl.bhu.ac.in/bhuir/handle/123456789/56428
dc.titleCORROSION RESISTANCE OF TWO MAGNETIC METALLIC GLASSES IN ACIDIC AND NEUTRAL AQUEOUS SOLUTIONS.
dc.typePublication
dspace.entity.typeArticle